IHP 130nm process: Difference between revisions

From ift
mNo edit summary
mNo edit summary
(17 intermediate revisions by 2 users not shown)
Line 5: Line 5:
The following steps describe how to install the Process Design Kit and start a new design.  
The following steps describe how to install the Process Design Kit and start a new design.  


Log on to one of the mikroservers:
Log on to the mikroserver:
  ssh -X mikroserver2
  ssh -X mikroserver4


The preferred shell is bash. When using another shell it will be necessary to change the installation routine and modify the initialization script accordingly.
The preferred shell is bash. When using another shell it will be necessary to change the installation routine and modify the initialization script accordingly.


First chose a parent directory, e.g.
The '''first time''' you are using the IHP design kit you should copy the user environment design to your chosen parent directory (e.g ~/ihp)
  cd ~/ihp
  cp -rp /eda/design_kits/ihp_sg13/SG13S_618_rev1.12.0/work/skel ~/ihp


Copy the user environment design and set general Cadence environment variables by doing:
Change sh.cadence in ~/ihp/cds to suit your needs. In particular you must define $IHP_TECH and $PROJECT according to your local environment. Then set general and user Cadence environment variables by doing:
  cp -rp /eda/design_kits/ihp_sg13/SG13S_616_rev1.0.2_a/work/skel .
  source /eda/cadence/2019-20/scripts/analog.sh
  source /eda/cadence/cadence_init.sh
cd ~/ihp/cds/
  source /eda/design_kits/ihp_sg13/sh.cadence
virtuoso &
 
To avoid having to do this every time try to set up your environment like described in [[MikroserverSetup]]
 
= Before starting designing =


Change cshrc.cadence in ~/ihp/skel/cds to suit your needs. In particular you must define $IHP_TECH and $PROJECT according to your local environment
Read the Design Kit User Guide. It can be found on the SG13SFeatures tab on the Virtuoso console window, or in the folder "/eda/design_kits/ihp_sg13/SG13S_618_rev1.12.0/doc/pdf/" on the mikroserver. Make sure that your web browser is closed or started from the mikroserver, else the file will not be found.
source ~/ihp/skel/cds/sh.cadence


Start the design environment by:
Other documents are found in "eda/design_kits/ihp_sg13/SG13S_618_rev1.12.0/doc/html/"
virtuoso &


Follow the Design Kit User manual found in the menu SG13S Features > Design Kit Documentation


[[Category:Mikroelektronikk]]
[[Category:Mikroelektronikk]] [[Category:Integrated_Circuts]] [[Category:Cadence_Virtuoso]]

Revision as of 11:30, 15 October 2020

Cadence design with IHP 130nm process

Starting up the IHP SG13S Design Kit

The following steps describe how to install the Process Design Kit and start a new design.

Log on to the mikroserver:

ssh -X mikroserver4

The preferred shell is bash. When using another shell it will be necessary to change the installation routine and modify the initialization script accordingly.

The first time you are using the IHP design kit you should copy the user environment design to your chosen parent directory (e.g ~/ihp)

cp -rp /eda/design_kits/ihp_sg13/SG13S_618_rev1.12.0/work/skel ~/ihp

Change sh.cadence in ~/ihp/cds to suit your needs. In particular you must define $IHP_TECH and $PROJECT according to your local environment. Then set general and user Cadence environment variables by doing:

source /eda/cadence/2019-20/scripts/analog.sh
cd ~/ihp/cds/
source /eda/design_kits/ihp_sg13/sh.cadence
virtuoso &

To avoid having to do this every time try to set up your environment like described in MikroserverSetup

Before starting designing

Read the Design Kit User Guide. It can be found on the SG13SFeatures tab on the Virtuoso console window, or in the folder "/eda/design_kits/ihp_sg13/SG13S_618_rev1.12.0/doc/pdf/" on the mikroserver. Make sure that your web browser is closed or started from the mikroserver, else the file will not be found.

Other documents are found in "eda/design_kits/ihp_sg13/SG13S_618_rev1.12.0/doc/html/"